Residential/Light Commercial Twin Tank Valve with precision control and immediate regeneration. Most standard softeners do not require gravel, though fine mesh (Iron Pro) systems or very large systems will. For water supplies with high levels of chlorine a carbon prefilter is recommended to extend resin life. After verifying programming run the system through a regeneration and watch the motor to ensure that it is moving the piston, if it is not the motor needs to be replaced. Once the resin is loaded and your tank is positioned you may finish filling the tank with water. Fleck 9100. Metered (Flow) Immediate - will regeneration immediately after programmed capacity is reached. The tank itself has a cap designed to keep the media in the tank, so once it is place in the correct position the contents will return to the bottom. Take the capacity of the system and divide by this number, this is your total capacity. This will reset all settings to default values, but leaves the volume remaining intact. To change the length of refill time, move the two pins at the end of the second group of holes as required. Overfilling the tank may lead to improper system operation. If you have more than one bag of resin the order does not matter and all of it should be used. To enter master programming, use the UP or DOWN button to set the time of day to 12:01 PM and press the Extra Cycle button to confirm the time setting. Digital SXT has LCD panel. Your system will ship with a cap designed to keep the resin in the tank during shipping. There is a slight depression that the lower basket will slip into when properly positioned. All the while saving you 10-15% on salt and capacity each time the system regenerates over the standard on demand single tanks. Once all the resin is loaded the tank will not be completely full, this is normal. The best way to alleviate this issue is to use a reverse osmosis (RO) system for your drinking water, as this will remove the sodium and provide bottled quality water. There are a few ways to do this. The valve handle(s) should be facing up when connecting it to the system. Drain fitting The SE controller has been discontinued for long enough it would be impossible to send one out anymore. Service Icon - Indicates the system is in service (working). It is a good idea to allow the system to run through a manual cycle. Email customercare@fleckvalves.com or call 1-800-581-3488 to Order Now! If your tank is a bit tilted, simply pick the tank up 2–3 inches (5–8 cm) off the floor and drop it gently but firmly down, favoring the side that needs to be adjusted to make the tank stand straight. FLECK®9000/9100/9500 Service Manual • 5 Changing Length of Brine Tank Refill Time The second group of holes on the program wheel determines the length of time the water conditioner refills the brine tank (2 minutes per hole). us. Fill tank partially with water -Optional-, Finish filling tank with water -Optional-, Attach the Control Head and Second Tank Adapter, If Present - Inspect and install top distributor basket, Screw on control head and second tank adapter, Connect overflow to floor drain -Optional-, © 2008-2021 Abundant Flow Water, Inc All Rights Reserved. If you prefilled the system it should only take a minute or two. The brine tank will come with the brine well loose, either inside the brine tank or in the box with the brine tank (). In general though the potassium chloride is not recommended (see Brine Tank section). Typically connected to the control head when received. We recommend verifying the control valve operation BEFORE plumbing to avoid issues. They have a 10 year warranty on tanks and a 5 year warranty on the valve and electronics. If you have read through these entire instructions and FAQ section and still have questions feel free to contact us for further help. No. Unoaded Systems This sets the length of the rapid rinse cycle. The system puts water into the brine tank at the end of every regeneration so it has a chance to dissolve the salt for the next cycle, so there will be water in the brine tank all the time. With proper installation and a little routine maintenance your system will be providing filtered water for many years. Sets regeneration frequency. To ensure proper operation, ensure that the drain line will not collapse or kink, and avoid installing any additional fittings (check valves, ball/gate valves, etc.) These are caps for the brine well. The exact fittings on your system may vary depending on the exact configuration of your system, but in general you will have a bypass valve and yoke, or a single piece bypass valve with built-in fittings (). KDF Media - Additive on some softeners - Gold or dark brown flakes Chemsorb/Filter-Ag/Turbidex - Used in sediment tanks and Air Injection Silver systems - Small whitish to yellowish chunks similar to small pebblesSmall beads, similar to wet sand, various colors. The 9100SXT is a dual-tank water softener which means you’ll never run out of soft water even when the system is regenerating - … Press the Extra Cycle button to advance to each setting shown below, and adjust with the UP/DOWN buttons if necessary. Thank you for purchasing a new AFWFilters® Water Softener. Flow Indicator - Flashes to indicate water is flowing through the system. This sets the length of the brine fill portion of the cycle. The MASTER programming section contains ALL of the available settings, including the settings shown in USER programming. --Using a hose, run water into the riser tube and gently push down on it as the water pushes the media away from the riser tube. If you have it, gravel will go in first, then the rest of the resin. You will supply the required fittings to connect from the system to your plumbing, this will typically consist of threaded adapters that will connect directly to the bypass/yoke, fittings to tie into your main line, and the copper/PVC/PEX line to connect between them. The copper pipe to connect between the tanks is not included, simply use two lengths of copper pipe long enough fit between the connections. Divide hardness in ppm or mg/L by 17.1 to get GPG. Plug the control head into a qualifying outlet as stated in the requirements section. Locate the brine fitting on the control head (). GFCI outlet is recommended. Some larger systems may ship partially loaded (with some media in the tank and some separate) or completely unloaded for easier placement. If you are installing more than one tank system the typical order for installation is: Fleck 5600-SXT Softener Installation & Start-Up Guide Thank you for purchasing a Clean Water System! Most systems will use default settings and there is very little that needs changed. For the average home the amount of sodium in the water will add little to your overall sodium intake (a single slice of regular bread will have 3-4 times as much sodium as a typical glass of softened water). Homes with high hardness or high water usage can expect higher salt usage. Quick Connect Fitting To calculate this number you will need to know the system capacity, (for example, a 48k system has a 48,000 grain capacity) and the hardness of the water in grains per gallon (GPG). Service and queued regeneration faucet icon Easy electronic programming LCD display alternates between ... FILTRATION & PROCESS FLECK LIGHT TWIN TANK VALVE FLECK® 9100 VALVE LIGHT COMMERCIAL/RESIDENTIAL TWIN TANK VALVE ... • This manual is intended as a guide for service of the valve only. If your riser tube is not exactly centered that is not an issue. Installer Manual Fleck 9100 - SXT - Generalities Ref. Any mixing of tank contents will correct itself after being placed in service. If your test shows hardness as parts per million (ppm) or milligrams per liter (mg/l) simply divide by 17.1 to get grains per gallon. Screws on top of the tank and controls the water flow and regeneration cycles. Refer to Brine Fill/Capacity Settings chart below. Since the brine tank has a float designed to stop the tank from overfilling, the most common cause of overfilling is the brine line not being securly connected to the float mechanism. You can run a manual regeneration and watch the brine tank during the brine draw cycle (BD on digital valves) to ensure the water is being drawn out of the tank, and during the brine fill (BF on digital) watch to see if water is coming out around the fitting. If the water seem very salty only occasionally and it clears up in a short amount of time the most common cause is water use during the regeneration cycle. It can also handle any level of water hardness. Fleck 5600 Metered Softener Cycle Details. Plug the unit back in and check the master programming and ensure valve type and system type are correct for your system. You can use the chart below to help. This image will show the differences for easy reference. The flow meter connects the control head and the bypass valve and it measures the water flow to initiate regeneration on demand. 9000-9100-9500 Service Manual Size: 2.6 mb . Data Dispaly - During programming shows setting. Water softeners work by exchanging sodium ions with the calcium and magnesium ions that make up hard water. Depending on your order your system will have either a single piece stainless steel bypass or a two part plastic bypass with yoke connection. If the time is flashing that indicates power was lost and the time needs to be set. This digital metered twin system saves you 15-25% in salt and water use every time the system cycles when compared to traditional metered single resin tank softeners. ... or it may take a couple of hours. It can be adjusted by simply pressing the UP or DOWN button repeatedly, holding down a button will cause time to change quickly. Watch the system as it steps through each cycle, make sure it moves to each position, that water is not leaking from any other fittings, and that water is flowing down the drain line. http://store.afwfilters.com/carbon-systems/. If you have KDF media (a very dense goldish or dark brown material) it will be added to the top of the tank. Compression Fitting If water is NOT being drawn out during the brine draw cycle and water is leaking around the fitting, it is not sealing correctly. Covers standard water softeners using a separate brine tank. Features. Please note that depending on your system you may not see all the options shown. If you have iron or manganese in the water you will need adjust the hardness to compensate. Add salt to the brine tank. The USER programming has the most commonly changed settings, and you can go through the settings below to get up and running quickly. Then our Fleck 9100SXT twin tank whole home water softener is what you need. Your chosen installation location and water supply must meet ALL of the following requirements: Use the following table to help verify the parts that are included with your system and verify that they are all accounted for. AC Press to validate the selection and move to the next regeneration cycle. This is normal, with the number displayed indicating the number of gallons until the next regeneration. That’s because the second tank of soft water acts as a backup, ready to immediately provide soft water once 100% of the first tank is used. Slowly open up the bypass valve just to the point of allowing water to enter the system at a trickle, and leave it like that until the tank is full of water. Most questions that arise are answered in this manual or the FAQ section at the end. If the water is saltier all the time that may be expected. You will heard two clicks. If you do not have a floor drain just leave the overflow as it is. Down Arrow - Used to change time or decrease value of current setting. Verify they are present and free from nicks or kinks. Do not use petroleum based lubricants like Vaseline. The overflow is gravity fed and can not be ran higher than the fitting itself. If your water has iron in it, we highly recommend using the Fleck 2510SXT Iron Filter System with you water softener. Instructions: Turn the knob located in the middle of the valve clockwise. If you have read through this manual and the FAQ section and still have a question that has not been answered feel free to use the AFWFilters website to contact us. A piece of tape or small bag will work, you just need to prevent resin from falling down the riser when you are loading it. Installation Instructions for Water Softeners with Fleck 9100 and 9100SXT. Make sure you know the direction of flow through your pipes. After soldering the copper pipe to the yokes, ensure the o-rings are lubricated and slide the yoke over the couplers on the second tank ports on the control head, and secure in place with the clips and screws. The funnel is a complementary item that MAY be included with some unloaded systems to help fill the polyglass tank with the resin. Studies have also shown that concerns over salt in the wastewater affecting septic systems are unfounded and not a problem. After pushing the bypass and control valve together, tighten the screws to secure the clips and hold everything in place. It is VERY unlikely that the pilot O-ring is missing. The resin goes in the polyglass tank, DO NOT load the resin in brine tank. Model 9000/9100/9500 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference ... Brine Tank Size & Salt Setting per Regeneration: _____ 9000/9100/9500 Control Valve Specifications:. Once plugged in, verify the system is receiving power and ensure the outlet is not on a switch that might get turned off. While systems that are installed correctly and fuctioning properly will not have issues, the top basket is included as a saftey measure to prevent problems and it is recommended to use it if present. After the adapters are in place the bypass assembly can be connected to the control head. Fleck 9000 9100 9500 Manual (Spanish) Pentair Residential Filtration Warranty From residential and business solutions that help people move, improve and enjoy their water, to our sustainable industrial applications, Pentair makes the most of life's essential resources. This offers vital information that can have major impact on your system/install/experience It is NOT an error code, if there is an error the error icon will be displayed and the error code will be the only thing displayed. Home » Fleck 9100 Control Valves » Fleck 9100 Twin Water Softener System With a twin-tank system featuring the Fleck 9100 valve, families benefit from soft water 24 hours a day, 7 days a week. When NOT in a cleaning cycle, the system is in a Service Position. We appreciate the opportunity you have given us to provide you with better water. Check your settings to ensure the system is setup to regeneration automatically. If it extends more than 1/3 inch above the top of the tank please refer to the FAQ section for ways to correct this. That being said, these instructions are designed as a general guideline for installation of your new system. Repeat on the other end, attaching to the second tank adapter. Up Arrow - Used to change time or increase value of current setting. The rate at which you use salt will vary depending on system size, settings, water quality, and water use. In most cases the amount of sodium added to the water is not noticable, but in homes with very high hardness or high sodium levels to begin with it may cause a salty taste to the water. Most concerns are related to the amount of water going down the drain, and a properly designed septic/sewer system will not have a problem handling it. h�bbd```b``V�+@$�X��n�`�%"GIƚ.�QD���{�����a`$@�g`�� � Once the water is cleared up a manual regeneration should be run. As long as the water is not up to the overflow there is no problem. The service icon does NOT mean your system needs serviced. That indicates an error. Sometimes the same media will be packaged in different bags, this is not uncommon. Do not overtighten the screws to avoid damage. If you have a floor drain available you can connect the overflow fitting to it using a flexible line. 340 0 obj
<>/Filter/FlateDecode/ID[<55B2A36D47A01146A6CBC1D3214AA250><84A355D0E8D84C47BD44AABA5FD9F4AD>]/Index[328 21]/Info 327 0 R/Length 77/Prev 797603/Root 329 0 R/Size 349/Type/XRef/W[1 3 1]>>stream
On digital systems, hold the extra cycle button for 5-10 second until the backwash starts. Fleck model 9000/9100/9500 service manual 40944 rev f no11 table of Pentair offers a variety ELITE 5600SE WATER SOFTENER MANUAL ___ fleck 9000 meter 1 #57339 rev. Installer manual Fleck 9100 SXT - Description 16 / 116 Ref. SE TIMER Page 4 Printed in U.S.A. Control Start-Up Procedures Display In normal operation the Time Of Day display alternates with Volume Remaining and Tank in Service displays ( 9000, 9100, 9500 SE Timer only). on the drain line, DO NOT overtighten the drain fitting (cracked drain ports are not covered under warranty), DO NOT use sealants on fittings (will invalidate warranty), PTFE (Teflon) tape and joint compound are fine, DO NOT connect the drain line to the brine tank. The bypass valve on your system allows for water to the system to be shut off for service or maintenance without shutting off the entire water supply. The display should light up and start flashing a time. Model 9000/9100/9500 7 16. As an example, if the water hardness is 24 GPG and you have a 48k system with 3 people, your gallon capacity would be (48,000/24)-(75x3)=1775 gallons. Day of the Week - will begin a regeneration cycle on the set day(s) at the set regeneration time. Push the tubing fully into the float, and tighten the nut, finger tight only. If your water is extremely hard or if you have high water use a larger reserve capacity may be needed. User Guide Fleck 9100-SXT 3.3. We are committed to providing the best customer experience possible and have provided these installation instructions to make things as simple as possible. To set your system, pull out the capacity knob and rotate the knob until the correct number is lined up with the white dot. This is fine, and when screwing on the control head just ensure the riser feeds into the pilot hole and it will correct itself. Make sure the system is set to regenerate at a time when no one will use water, and make sure you do not have anything that may automatically use water while the system is regenerating. On loaded and partially loaded systems, the riser tube may get pushed off-center during shipping. Use a silicone lubricant or vegetable oil to both O-rings. This is an internal designation only and does NOT mean you received the SE. You can also use the contact us link above to connect you to one of our technical experts. %PDF-1.6
%����
You would line the white dot up between the numbers 17 & 18. Most common questions are answered in the instructions or FAQ section. Time Clock - will regeneration at the set regeneration time after the set number of days has passed. It is recommended to attach the adapters to the bypass or yoke BEFORE connecting to the control head to avoid damage. Turn manual knob so that the micro switch rides on the first set of pins. Depending on system configuration your system may include a top distributor basket (). Pictures are included to help identify common parts, components, and connections, so what you have may vary slightly from what is pictured. A physical air gap of at least 3 inches (76 mm) between the end of the drain line and the wastewater level in the drain pipe should be used to avoid contamination of the line. Make sure to follow all applicable local plumbing codes. endstream
endobj
startxref
This cycle can be skipped during the initial startup by pressing the extra cycle button after the [BD] cycle has started counting down. As treated water is used, the Volume Remaining display counts down (in gallons) from a maximum value to zero or (----). If you have the compression style fitting, remove the nut from the float and place on the brine line as shown (). If error still occurs contact us for support. The one on the top helps prevent salt from falling down into the brine well and messing with the float assembly. Drain line is not included, since every installation is different and will require different lengths, styles, and sizes of drain line. By-passing If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture below. Once your system is near the installation location, remove the cap at the top of the tank by unscrewing it counterclockwise. Most people who want to use potassium chloride are concerned about the salt it is putting in the water. Carbon/Catalytic carbon - Used in stand alone system, Air Injection Gold systems, and some combo systems - Black media, fairly lightweight, similar to finely crushed charcoal Subtract the reserve capacity from the total capacity and this is how many gallons you will set your system to. If unsure of the size of your system you may contact us for assistance. Using a piece of flexible 3/8 inch tubing, place the fittings on the tubing as shown () and connect it to the control head. Hand tighten only. Allow water to run out of the faucet until no more air comes out, then close the faucet. Start with the soft reset, and if that does not solve the problem move on to the master reset. DO NOT use additional fittings (check valves, ball valves, etc.) A later step will have the control head put the correct amount of water in the brine tank for you. Hold Extra Cycle and Down buttons for 25 seconds. If you have a second one it can be used on the bottom, but it doesn't really serve purpose and can be saved as a spare if you prefer. 328 0 obj
<>
endobj
Since the system cleans itself most particulate in the water will be trapped and rinsed off by the regeneration cycle, eliminating the need for a sediment prefilter. Unloaded Systems ONLY When flashing a regeneration will run at the programmed time. 5600 se valve 1 / 2. It is a good idea to allow the system to run through a manual cycle. The pilot O-ring is up inside the control head and you will usually have to reach up inside to feel it, it is almost impossible for it to come out. Most standard softeners do NOT use gravel, though Iron Pro/Fine Mesh softeners and very large softeners will. On the 9100/9100SXT valve use the tube assembly to connect the main control valve to the second tank adapter (). A tall slender tank 44–65 inches in height with an opening on the top. The display will show the time as currently programmed in the system. Extra Cycle Button - Used to initiate manual regeneration or advance through programming. Some SXT systems may have labels referring to the older SE model number. If using a softener for iron removal, then the carbon filter will typically follow after the softener. If you are having a hard time fitting your hand between the float and the brine well to secure the overflow nut you can remove the float by removing the nut that holds the float in place. Hardness in grains per gallon (GPG). as this can prevent proper flow down the drain, which can lead to poor performance and premature system failure. Partially Loaded Systems - Continue to the next step. FLECK – PENTAIR WATER 9000 – 9100 – 9500 fleck-orderguide.com Initiate a manual regeneration, -1/30 de Fleck Water Softener Parts – Fleck Water Softener Rebuild read all instructions carefully before operation. Includes O-rings (already attached) to seal the connection and screws and clips to secure the connection. Use the result here. Fleck 9100 SXT Twin Tank On Demand Water Softener. Only used on metered water softners, it indicates water is flowing through the system. Take the average number of people in the home and multiply by 75. If you are unsure what you have feel free to contact us to ensure you place the media in the correct tank. These systems can be ran to your sewer or septic line and is typically the recommended place to run the drain. The control head can be plugged in and operated without water, this will not damage the control head. Do not cut your riser tube! The system uses O-rings to provide a water tight seal, and after checking each O-ring for any obvious damage a small amount of silicone lubricant or vegetable oil can be used to help ensure a good seal. Make sure to put it back when you are finished. It is a good idea to dry fit all your connections before cutting into your plubing and finalizing them to ensure everything lines up like it should and that you have everything you need. Please read through the entire instruction manual carefully. Covers standard water softeners using a separate brine tank. As an example, if the water hardness is 12 GPG, iron is 2.5 ppm, manganese is 0.5 ppm your compensated hardness is is 12+(3x4)=12+12=24 GPG. Doing so will require emptying and reloading the system. Typically set to midnight or 2am to ensure water is not being used. Check the meter to ensure it is not stuck and that the gallons remaining is counting down.
Most standard softeners do not require gravel, though fine mesh (Iron Pro) systems or very large systems will. Ensure the riser tube is positioned in the middle of the tank. If error occurs again contact us for support.